Unmatched Efficiency
And Flexibility

Customized
Office Environments

  • Quality workspace designs for healthy, safe work environments
  • Large and highly efficient floor plates
  • Tall ceiling heights at 11’ (Levels 2-4) and 10’ (Levels 5-10)
  • Natural daylighting via full height glass on all tenant floors to maximize sunlight, outdoor tenant areas and mountain views.
  • PRIVADA restroom partitions blending modern design with high-end aesthetics and maximum privacy
  • Touchless lavatory fixtures to reduce touchpoints

Ground
Floor Plan

22,000 RSF

Download PDF

TYPICAL
LOW RISE
FLOOR PLAN

Levels 2-4
41,000 RSF

Download PDF

TYPICAL
HIGH RISE
FLOOR PLAN

Levels 5-8
30,840 RSF

Levels 9-10
29,300 RSF

Download PDF

Building
Section

  • 327, 000 RSF Class a Office
  • Large Efficient floors with low common area factors
  • Expansion opportunities of up to 326,000 RSF is available in 645 W. Temple, a future adjacent office building planned as a second phase

Building

FLOOR PLATES

Floor Area

Average size
41,000 RSF (Levels 2-4)
30,840 RSF (Levels 5-8)
29,300 RSF (Levels 9-10)

Perimeter Column

30′ typical with column-free corners

Lease Spans

46′ typical core wall to exterior wall

Floor-to-Floor Heights

15′ (Levels 2-4)
14′ (Levels 5-10)

Clear Heights

15′ to ceiling (Level 1)
11′ to ceiling (Levels 2-4)
10′ to ceiling (Levels 5-10)

CORE & LOBBY

Lobby

Class A lobby has stone floors; walls are accented with stone, wood and stainless steel

Elevators

5 passenger, 1 service
service lobby enclosed within core, secured

Closet Space

Electrical and tel/data
IDF closets on each floor

Fire Stairs

Pressurized stair shafts;
oversized to accommodate a higher occupant load

Restrooms

Privada toilet compartments blending modern design with high-end aesthetics and maximum privacy. Finishes include crisply designed ceramic tile floor and walls, vinyl wall covering accents, stone countertops; restrooms accessible from both sides of the core on typical floors; touchless lavatory fixtures

EXTERIOR WALL

Perimeter Windows

Full-height, floor-to-ceiling

Window Module

5′ typical mullion spacing

Integral Window Shades Pockets

Integrated pocket within mullion system

Vission Glass

Dual pane insulated units with a low-E coating

BUILDING SYSTEMS

Structural Floor System

Composite deck consisting of concrete on metal deck with shear studs fastened to beams

Columns

Structural steel columns

Lateral Load Resisting System

Structural steel braced frames around core to resist buckling

Live Load

50 PSF + 15 PSF for partition for office area and 100 PSF for core area

BUILDING SYSTEMS

HVAC

High quality antimicrobial MERV-13 air filters

UV-C Lamps

Improved indoor air quality by preventing microbial growth on outdoor air cooling coils and drain pan surfaces

Ventilation

Active ventilation, filtration and humidity control with ASHRAE guidelines to reduce potential for airborne exposure

Advanced BAS

Automatically adjust building temperature to maintain an ideal level of comfort; 24/7 system monitoring